Determining test pressure and hold time

Short answer

Test pressure and hold time are not determined by a single factor picked from the internet. They are defined by an authorized technical person after reviewing together the applicable edition of the relevant product and test standard, the manufacturer's assembly instructions and the purchase specification.

Source: S013, S017, S030

Relationship between working, test and burst pressure
V008 · Original explanatory diagram; not a numerical product approval. (labels in Turkish)

Technical explanation

ISO 1402 covers hydrostatic test methods, while ISO 7751 addresses the ratios of proof and burst pressure to working pressure. These different scopes do not show that all hoses can be tested with the same factor under all conditions. Rubber, plastic, metal and composite assemblies must not be automatically placed in the same test scope. The test medium and measurement conditions are also evaluated together with the result.

Source: S013, S017, S030

Topic-specific checkpoints

ItemDescription
ProductMaterial, assembly type and scope
BasisProduct standard and manufacturer instructions
TargetPressure, duration, medium and acceptance criterion
ConflictDocumented technical assessment

Source: S013, S017, S030

How to evaluate it in practice

On the work order, separate the working pressure from the test pressure field. Write the source document and clause next to the target value; do not add a clause of a standard that has not been read as if it existed. If two documents conflict, do not allow the operator to choose the higher one; open a technical resolution record. No application procedure for pressurizing the test in the field is given here. This operation requires a guarded test setup and trained, authorized personnel.

Original editorial recommendation; not a clause of a standard.

Frequently asked questions

Is twice the working pressure always the correct test pressure?

No. The factor and other conditions must be verified from the relevant product, method and contract scope.

Source: S013, S017, S030

Source coverage

  1. S013
    ISO 1402:2021 ISO · accessed 2026-10-19 Abstract; General information
  2. S017
    Parker Safety Guide, Publication 4400-B.1 Parker Hannifin · accessed 2026-10-20 PDF page 2; 2.2 PressurePDF page 3; 3.1 Component Inspection, 3.2 Hose and Fitting Assembly and 3.3 Related Accessories
  3. S030
    ISO 7751:2016 ISO · accessed 2026-10-19 Abstract; General information

A169 · Revision 5 · Content date 2026-10-20 · Published 2026-10-20 · Translated from the Turkish original.