Fitting and clamp systems for steam hose
Steam hose connections must be a system suitable for steam service and verified with the hose. A general hose clamp, a fitting of similar diameter or an assembly that looks sound is not sufficient. Assembly, inspection …
-
Using elbows and rigid pipe at a steam line outlet
Considering a suitable elbow or rigid pipe section instead of changing direction immediately at the hose outlet can reduce tight bending of the hose. However, the new part must be designed together with pressure, temper…
-
Bending and support plan for steam hose
Supports on a steam hose must carry the weight without crushing, twisting or forcing the hose to a tight radius. The load near the connection and the entire route are assessed together. A single universal support spacin…
-
Protection against hot surface contact
Hot surface protection is selected for defined risks such as operator contact and external heat exposure. Adding a heat sleeve does not automatically increase the hose's resistance to the internal steam temperature. The…
-
Safety questions before disconnecting a steam line connection
Before a steam connection is disconnected, energy isolation, residual pressure, temperature and trapped fluid must be assessed with a safe procedure. A valve appearing closed does not on its own prove that the assembly …