Data required for a pressure loss calculation

Short answer

Flow rate and nominal diameter alone are not sufficient for a pressure loss calculation. The actual inside diameter, length, fluid properties, temperature, connections and flow regime are required. A single reliable loss value cannot be produced with incomplete data.

Source: S021, S024

Technical explanation

The flow cross-section and volumetric flow rate determine the mean velocity, but flow resistance also depends on the line configuration and fluid behavior. Manufacturer selection guides address size, fluid and application conditions together. If a pressure loss curve in a catalog is based on specific test conditions, it must not be transferred directly to a different liquid or temperature. A connection of the same nominal size as the hose can have a different actual flow cross-section.

Source: S021, S024

Topic-specific checkpoints

ItemDescription
GeometryActual diameter, length and line layout
FluidDensity and viscosity at temperature
FlowFlow rate and assessment of the applicable flow regime
Local resistanceFittings, couplings, elbows and valves

Source: S021, S024

How to evaluate it in practice

In the proposed data form, collect the total hose length, actual inside diameter, list of connections and valves, flow rate, fluid density/viscosity information and temperature. Mark narrow passages and abrupt changes of direction separately. The technical lead should choose the calculation method and the sources of coefficients. A reliable pressure loss cannot be calculated with missing coefficients; this guide aims first to complete the necessary data. Plan separately how the calculation result will be checked against a measurement or a manufacturer curve.

Original editorial recommendation; not a clause of a standard.

Frequently asked questions

Do two hoses of the same diameter and length have the same pressure loss?

Not necessarily, if the internal construction, actual diameter, fluid conditions and connections differ.

Source: S021, S024

Source coverage

  1. S021
    Selecting a hose assembly? Remember STAMPED Swagelok Bangalore · accessed 2026-10-19 Size; Temperature; Application; Material; Pressure; End Connections; Delivery
  2. S024
    Hose and Flexible Tubing, MS-01-180 Swagelok · accessed 2026-10-19 PDF pages 4–5 / printed 253–254: Nomenclature; pages 8–9: selection, installation and use

A210 · Revision 4 · Content date 2026-10-19 · Published 2026-10-20 · Translated from the Turkish original.